MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/bme-211313

Медицинская библиотека · Bio-medical materials and engineering · 2022

Finite element analysis of new headless compression supporting screw for the treatment of unstable femoral neck fracture.

Xue Yang, Wang Xiong-Fei, Zhao Fu-Long, Han Da-Cheng, Long An-Hua, Wang Jin, Zhang Ya-Kui, Wang Xue-Fei

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Femoral neck fracture is an unsolved challenge in orthopedics. The complication rate in particular is high. There remains a lack of consensus on the optimal choice of internal fixation for unstable femoral neck fracture.

OBJECTIVE

The study aimed to develop a new headless compression supporting screw (HCSS) for the treatment of unstable foemoral neck fracture.

METHODS

We designed a new HCSS and used a femoral neck fracture (Pauwels III fracture) model (left, fourth-generation composite, Sawbones) and three-dimensional finite element analysis to compare the biomechanical performance of HCSSs with that of cannulated compression screws (CCSs) for treatment of unstable femoral neck fracture.

RESULTS

Maximum displacement, peak von Mises stress, peak strain, and rotation for the HCSS were smaller than those for the CCS. The stress was more widely distributed for the HCSS, whereas the stress was concentrated for the CCS.

CONCLUSIONS

The HCSS resulted in better biomechanical stability than that from the CCS. For Pauwels III fractures the HCSS exhibits better resistance to shear forces and better support, providing a new clinical treatment.

Для цитирования: Xue Yang, Wang Xiong-Fei, Zhao Fu-Long, Han Da-Cheng, Long An-Hua, Wang Jin, Zhang Ya-Kui, Wang Xue-Fei. Finite element analysis of new headless compression supporting screw for the treatment of unstable femoral neck fracture.. Bio-medical materials and engineering. 2022. DOI: 10.3233/bme-211313.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.