DOI 10.1097/yct.0000000000000251
Electroconvulsive Therapy Under General Anesthesia With Cisatracurium, Laryngeal Mask Airways, and Bispectral Index.
Аннотация
OBJECTIVES
Electroconvulsive therapy (ECT) has dramatically reduced musculoskeletal complications when carried out with muscle relaxants under general anesthesia. However, seizure quality can be affected by the depth of anesthesia and choice of anesthetic agent. The purpose of this study was to describe a general anesthetic technique for ECT by using laryngeal mask, bispectral index (BIS), and muscle relaxant monitoring.
METHODS
Twenty-one patients, between ages 18 and 70 years (American Society of Anesthesiologists physical status I-III), who underwent a total of 89 sessions of ECT were examined in a retrospective study. Anesthesia was induced by use of propofol (1.0 mg/kg) followed by cisatracurium (0.2 mg/kg). The BIS, train-of-four, and end-tidal carbon dioxide were all monitored continuously. A laryngeal mask airway was used to maintain and protect the airway during the procedure. Electroconvulsive therapy stimuli were applied bilaterally when the train-of-four was assessed as being zero and BIS scores were 70. All patients then received 5 μg sufentanil and 2 mg midazolam, while titrated to maintain the BIS value at 40 to 50, before the muscle relaxation exhibited complete recovery.
RESULTS
The mean duration of treatment process takes approximately 82.5 minutes. Mean (SD) seizure length was 58.8 (28.3) seconds, with 4.5% incidence of restimulation per treatment. Incidence of awareness was 0%. No patients exhibited delirium, nausea, vomiting, or myalgia in the postseizure phase.
CONCLUSIONS
Bispectral index monitoring of the depth of anesthesia may have improved seizure quality, and awareness did not occur.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.