MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-017-2773-0

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2017

Minimally invasive plate augmentation in the treatment of long-bone non-unions.

Park Ki-Chul, Oh Chang-Wug, Kim Joon-Woo, Park Kyeong-Hyeon, Oh Jong-Keon, Park Il-Hyung, Kyung Hee-Soo, Heo Jeong

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Exchange nailing is most acceptable for treating hypertrophic non-union of the long bones, requiring the removal of previously fixed implant. However, its main effect of mechanical stabilization is controversial in non-isthmal area. We hypothesized that minimally invasive plate augmentation over the non-union site may have a better option, without the need of bone grafting or removing pre-existing implants.

MATERIALS AND

METHODS

Seventeen patients with hypertrophic non-union of the long bones between 2010 and 2014 on radiography who previously underwent intramedullary (IM) nailing or plate osteosynthesis for long-bone fractures were included. A locking compression plate was inserted with at least three mono- or bicortical screws at each proximal and distal segment. Broken or loosened interlocking screws of IM nail were simultaneously re-fixed. Fracture site exposure, pre-fixed implant removal, and bone grafting were not performed. We investigated whether union occurred and analyzed functional outcomes and complications.

RESULTS

Eleven femoral and six tibial non-unions were prospectively included. In the pre-existing implants, 13 nails and 4 plates were found. All cases achieved union at a mean 22.7 weeks. One case of superficial infection was managed with oral antibiotics. Deep infection or implant failure did not occur.

CONCLUSIONS

Minimally invasive plate augmentation can achieve additional stability and promote healing of hypertrophic non-union of the long bones. When indicated, this technique is the least invasive alternative to exchange nailing and reduces surgical risks in the treatment of diaphyseal non-union.

Для цитирования: Park Ki-Chul, Oh Chang-Wug, Kim Joon-Woo, Park Kyeong-Hyeon, Oh Jong-Keon, Park Il-Hyung, Kyung Hee-Soo, Heo Jeong. Minimally invasive plate augmentation in the treatment of long-bone non-unions.. Archives of orthopaedic and trauma surgery. 2017. DOI: 10.1007/s00402-017-2773-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.