MedElevator Войти в исследования
← Поиск публикаций

DOI 10.19723/j.issn.1671-167x.2023.05.011

Медицинская библиотека · Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences · 2023

[Near-infrared targeted probe designed for intraoperative imaging of prostatic neurovascular bundles].

Zhang Zhan Yi, Zhang Fan, Yan Ye, Cao Cai Guang, Li Chang Jian, Deng Shao Hui, Sun Yue Hao, Huang Tian Liang, Guan Yun He, Li Nan, Lu Min, Hu Zhen Hua, Zhang Shu Dong

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the imaging effect of a near-infrared fluorescent targeted probe ICG-NP41 on the neurovascular bundles (NVB) around the prostate in rats.

METHODS

A near-infrared fluorescent targeted probe ICG-NP41 was synthesized. An animal model for NVB imaging was established using Sprague-Dawley rats (250-400 g). Experiments were conducted using a custom-built near-infrared windowⅡ(NIR-Ⅱ) small animal in vivo imaging system, and images collected were processed using ImageJ and Origin. The fluorescence signal data were statistically analyzed using GraphPad Prism. The signal-to-background ratio (SBR) for NVB was quantitatively calculated to explore the effective dosage and imaging time points. Finally, paraffin pathology sections and HE staining were performed on the imaging structures.

RESULTS

Except for rats in the control group (n=2), right-sided NVB of the rats injected with ICG-NP41 (n=2 per group) were all observed in NIR-Ⅱ fluorescence mode 2 h and 4 h after administration. At 2 h and 4 h, average SBR of cavernous nerve in 2 mg/kg group in fluorescence mode was 1.651±0.142 and 1.619±0.110, respectively, both higher than that in white light mode (1.111±0.036), with no significant difference (P>0.05); average SBR of 4 mg/kg group in fluorescence mode were 1.168±0.066 and 1.219±0.118, respectively, both higher than that in white light mode (1.081±0.040), with no significant difference (P>0.05). At 2 h and 4 h, the average SBR of 2 mg/kg and 4 mg/kg groups in fluorescence mode were higher than that of the control group (SBR=1), the average SBR of the 2 mg/kg group was higher than that of the 4 mg/kg group, and all the above with no significant difference (P>0.05). The average diameter of the nerve measured by full width at half maxima method was about (178±15) μm. HE staining of paraffin sections showed the right major pelvic ganglion.

CONCLUSION

The near-infrared fluorescent targeted probe ICG-NP41 can be used for real-time imaging of the NVB around the prostate in rats, providing a potential feasible solution for localizing NVB in real time during nerve-sparing radical prostatectomy.

Для цитирования: Zhang Zhan Yi, Zhang Fan, Yan Ye, Cao Cai Guang, Li Chang Jian, Deng Shao Hui, Sun Yue Hao, Huang Tian Liang, Guan Yun He, Li Nan, Lu Min, Hu Zhen Hua, Zhang Shu Dong. [Near-infrared targeted probe designed for intraoperative imaging of prostatic neurovascular bundles].. Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences. 2023. DOI: 10.19723/j.issn.1671-167x.2023.05.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.