Wear of bulk-fill resin composites.

Osiewicz Magdalena A, Werner Arie, Roeters Franciscus J M, Kleverlaan Cornelis J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Bulk-fill resin composites are a special group of restorative materials designed to reduce chair time needed to insert a direct composite restoration. However, other factors determine the clinical success of a restorative material. Clinically the major reasons for failure of direct restorations are secondary caries and fracture of the restoration or the tooth itself. In the long-term composite resin restorations in posterior teeth may be prone to wear. As bulk-fill materials have their own composition that will determine their mechanical properties, the wear resistance may be affected as well. The aim of this in vitro study was to evaluate the wear of bulk-fill composites in comparison with a conventional hybrid composite. The null hypothesis was that there are no differences between the four bulk-fill materials and one traditional highly filled nanohybrid composite for posterior use when subjected to a two-body wear rate test and hardness measurement.

METHODS

Four bulk-fill composites SDR Smart Dentin Replacement (SDR), X-tra base (XBA), FiltekBulk Fill (FUP), Dual-Curing Bulk Composite (FBFL) and conventional nanohybrid resin composite Grandio (GDO) subjected to a two-body wear test against a stainless steel (SS) antagonist wheel. Scanning Electron Microscopy analysis was performed to detect the surface alterations. Microhardness of all samples was tested (n = 5) with a Vickers diamond indenter (5 indentations in each specimen). One-way ANOVA and Tukey's post hoc test (P < 0.01) were used to analyze differences in wear values. The hardness data were submitted to one-way ANOVA test, followed by the Tukey post hoc test (α = 0.05). T-test was applied to compare wear rate in time interval between one day and one month.

RESULTS

The highest wear rate values were recorded for SDR and the lowest wear rate values were for GDO. Hardness was the highest for GDO and the lowest for FBFL.

SIGNIFICANCE: The bulk-fill composites have a higher wear rate and lower hardness than the conventional nanohybrid composite, making them less suitable for stress-bearing restorations.

Для цитирования: Osiewicz Magdalena A, Werner Arie, Roeters Franciscus J M, Kleverlaan Cornelis J. Wear of bulk-fill resin composites.. Dental materials : official publication of the Academy of Dental Materials. 2021. DOI: 10.1016/j.dental.2021.12.138.