Preclinical study of additive manufactured plates with shortened lengths for complete mandible reconstruction: Design, biomechanics simulation, and fixation stability assessment.

Shi Qimin, Sun Yi, Yang Shoufeng, Van Dessel Jeroen, Lübbers Heinz-Theo, Zhong Shengping, Gu Yifei, Bila Michel, Politis Constantinus

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A combination of short titanium plates fabricated using additive manufacturing (AM) provides multiple advantages for complete mandible reconstruction, such as the minimisation of inherent implant deformation formed during AM and the resulting clinical impact, as well as greater flexibility for surgical operation. However, the biomechanical feasibility of this strategy is still unclear, and therefore needs to be explored.

METHOD: Three different combinations of short mandible reconstruction plates (MRPs) were customised considering implant deformation during the AM process. The resulting biomechanical performance was analysed by finite element analysis (FEA) and compared to a conventional single long MRP.

RESULTS

The combination of a long plate and a short plate (Design 3 [LL61 mm/RL166 mm]) shows superior biomechanical properties to the conventional single long plate (Design 1 [TL246 mm]) and reveals the most reliable fixation stability among the three designs with short plates. Compared to conventional Design 1, Design 3 provides higher plate safety (maximum tensile stress on plates reduced by 6.3%), lower system fixation instability (relative total displacement reduced by 41.4%), and good bone segment stability (bone segment dislocation below 42.1 μm) under masticatory activities.

CONCLUSIONS

Preclinical evidence supports the biomechanical feasibility of using short MRPs for complete mandible reconstruction. Furthermore, the results could also provide valuable information when treating other large-sized bone defects using short customised implants, expanding the potential of AM for use in implant applications.

Для цитирования: Shi Qimin, Sun Yi, Yang Shoufeng, Van Dessel Jeroen, Lübbers Heinz-Theo, Zhong Shengping, Gu Yifei, Bila Michel, Politis Constantinus. Preclinical study of additive manufactured plates with shortened lengths for complete mandible reconstruction: Design, biomechanics simulation, and fixation stability assessment.. Computers in biology and medicine. 2021. DOI: 10.1016/j.compbiomed.2021.105008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.