Artifacts in OCT Retinal Nerve Fiber Layer Imaging in Patients with Boston Keratoprosthesis Type 1.

Castillejos Alexandra G, Devlin Julia, Saini Chhavi, Sun Jessica A, Wang Mengyu, Johnson Grace, Chodosh James, Shen Lucy Q

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

PURPOSE: To determine the clinical utility of OCT retinal nerve fiber layer (OCT RNFL) imaging for glaucoma evaluation in patients with Boston keratoprosthesis type 1 (KPro) by investigating imaging artifacts.

DESIGN

Case-control study.

SUBJECTS: Patients with KPro and without KPro (controls) matched for age, gender, and glaucoma diagnosis.

METHODS

The most recent Cirrus OCT RNFL scan from 1 eye was categorized as having good signal strength (SS; ≥ 6 out of 10) or poor SS (< 6). Those with good SS were analyzed by 2 independent reviewers for artifacts. Images with good SS and no artifacts affecting the scanning circle were considered useful for glaucoma evaluation.

MAIN OUTCOME MEASURES: The incidence of poor SS and artifacts in OCT RNFL images; patient characteristics associated with useful scans.

RESULTS

Sixty-five patients with KPro and 75 controls were included; 89.2% of KPro patients and 89.3% of control subjects had glaucoma (P = 0.98). Forty percent of KPro patients and 5.3% of controls had poor SS (P < 0.001). The proportion of images with either poor SS or artifacts was similar in KPro (76.9%) vs. controls (72.0%, P = 0.51). The most common artifacts in both groups were missing data (43.6%, 53.2%, respectively, P = 0.32) and motion artifact (25.6%, 19.7%, respectively, P = 0.47). Images were useful for glaucoma evaluation in 43.1% of KPro patients and in 69.3% of controls (P = 0.002). In the KPro group, patients with useful OCT scans, compared with those without, had better visual acuity (0.4 ± 0.3 vs. 0.9 ± 0.7 logarithm of the minimum angle of resolution, P = 0.004), and did not have congenital corneal pathologies (0.0% vs. 24.3%, P = 0.008). A multivariate analysis showed that KPro patients with older age had higher odds of useful OCT images (odds ratio, 1.05; P = 0.03). Among KPro patients with useful OCT scans, retinal nerve fiber layer thickness correlated with observed cup-to-disc ratio (Pearson correlation: r = -0.42, P = 0.03).

CONCLUSIONS

The rate of OCT RNFL images with either poor signal strength or artifacts in the KPro and control population was comparable. In patients with KPro, where intraocular pressure measurements are difficult and glaucoma is highly prevalent and often severe, OCT RNFL imaging can be useful for glaucoma evaluation.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Для цитирования: Castillejos Alexandra G, Devlin Julia, Saini Chhavi, Sun Jessica A, Wang Mengyu, Johnson Grace, Chodosh James, Shen Lucy Q. Artifacts in OCT Retinal Nerve Fiber Layer Imaging in Patients with Boston Keratoprosthesis Type 1.. Ophthalmology. Glaucoma. 2023. DOI: 10.1016/j.ogla.2023.09.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.