MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-021-04775-8

Медицинская библиотека · BMC musculoskeletal disorders · 2021

Excellent clinical and radiological outcome following locking compression plate fixation of displaced medial clavicle fractures.

Wurm Markus, Siebenlist Sebastian, Zyskowski Michael, Pflüger Patrick, Biberthaler Peter, Beirer Marc, Kirchhoff Chlodwig

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Treatment of medial clavicle fractures is still controversially discussed in the community of upper extremity surgeons. An increasing number of symptomatic non-unions following conservative treatment of displaced fractures led to the development of various surgical approaches. Aim of this study was to evaluate the clinical and radiological outcome following operative treatment of displaced medial end clavicle fractures.

METHODS

Patients who presented with a displaced fracture of the medial clavicle between September 2012 and December 2019 were retrospectively enrolled in this study. All patients were operatively treated with open reduction and internal fixation (ORIF) using an anatomically precontoured locking compression plate (LCP) originally designed for the lateral clavicle (Synthes®, Umkirch, Germany). Functional outcome was recorded using the American Shoulder and Elbow Surgeons (ASES) Score, the Munich Shoulder Questionnaire (MSQ), Shoulder Pain and Disability Index (SPADI) and Constant Score.

RESULTS

Overall 18 patients with a mean age of 54.5 ± 23.5 years suffering from a displaced fracture of the medial clavicle were identified. The mean follow-up was 40.9 ± 26.2 months. The mean ASES accounted for 88.3 ± 20.8 points, the mean MSQ was 83.1 ± 21.7 points, the mean SPADI was 85.6 ± 22.5 and a mean normative age- and sex-specific Constant Score of 77.5 ± 19.1 points resulted. No minor or major complications were observed. Radiologic fracture consolidation was achieved in all patients after a mean of 6.4 months.

CONCLUSION

Surgical treatment of displaced medial clavicle fractures using an anatomically precontoured locking plate originally designed for the lateral clavicle led to very good to excellent clinical and functional results.

TRIAL REGISTRATION: No: DRKS00024813 , retrospectively registered 19.03.2021 ( www.drks.de ).

Для цитирования: Wurm Markus, Siebenlist Sebastian, Zyskowski Michael, Pflüger Patrick, Biberthaler Peter, Beirer Marc, Kirchhoff Chlodwig. Excellent clinical and radiological outcome following locking compression plate fixation of displaced medial clavicle fractures.. BMC musculoskeletal disorders. 2021. DOI: 10.1186/s12891-021-04775-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.