Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System.
Аннотация
BACKGROUND
The original knee megaprostheses with fixed or rotating hinge articulation were custom made and only used for reconstruction of the knee following distal femoral or proximal tibial tumor resections. The aim of the study was to analyze the short- and mid-term results of revision total knee arthroplasty with Global Modular Replacement System (GMRS) used in difficult situations not amenable to reconstruction with standard total knee replacement implants.
MATERIALS AND
METHODS
Nine patients (9 knees) were treated with this comprehensive modular implant system, with a mean age of 73.7 years (range 56-83 years) and a mean followup of 5 years (range 3-8 years). Two patients were treated for distal femoral nonunion, five for distal femur periprosthetic fracture and two for periprosthetic joint infection.
RESULTS
The mean Knee Society Score: Knee and functional scores were 77.9 and 40 points, respectively. All demonstrated full extension and flexion was at least 90°. Recurrence of infection was present in one patient. No signs of loosening, dislocation, or implant failure were observed.
CONCLUSIONS
Based on our small series of patients that represent severe cases, GMRS provides relatively good mid-term functional results, pain relief, and good implant survivorship with a low complication rate. This salvage procedure allows elderly, infirm patients to regain early ambulatory ability.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.