DOI 10.1016/s2255-4971(15)30372-4
A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY.
Аннотация
OBJECTIVE
To describe and clinically and radiographically compare patients who underwent total knee arthroplasty (TKA) with all-polyethylene (ALP) and metal-backed (MTB) tibial implants.
METHODS
Patients who underwent TKA between January 1988 and December 2004 were grouped according to the type of implant received: all-polyethylene or metal-backed. Sixty patients came for evaluations, totaling 82 operated knees. Among these, 22 patients had undergone TKA only with ALP (12 unilateral and 10 bilateral cases), 33 patients only with MTB (26 unilateral and 7 bilateral cases) and five patients underwent TKA with ALP in one knee and MTB in the other. The knees were divided thus: group 1, 37 knees with ALP; and group 2, 45 knees with MTB.
RESULTS
There were no differences in clinical or functional evaluations between the groups. The mean radiolucency in the femur was 0.838 mm for the patients in group 1 and 0.356 mm for the patients in group 2 (p = 0.049). For the tibia, in the AP view, there was a mean value of 2.703 mm for group 1 and 0.733 mm for group 2 (p = 0.000). In the lateral view, the mean values for osteolysis was 0.405 mm for group 1 and 0.200 mm for group 2 (p = 0.074).
CONCLUSIONS
There were no differences between the groups in the functional and clinical evaluations. However, greater radiolucency was observed in the arthroplasties with ALP, both in the femur in the lateral view and in the tibia in the AP view. Level of evidence IV - case series study.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.