MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-021-01800-2

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2021

3D virtual pre-operative planning may reduce the incidence of dorsal screw penetration in volar plating of intra-articular distal radius fractures.

Prijs Jasper, Schoolmeesters Bram, Eygendaal Denise, de Vries Jean-Paul P M, Jutte Paul C, Doornberg Job N, Jaarsma Ruurd L, IJpma Frank F A, Traumaplatform 3D Consortium

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the effect of three-dimensional virtual pre-operative planning (3DVP) on the incidence of dorsal screw penetration after volar plating of distal radius fractures.

METHODS

A cross-sectional diagnostic imaging study was performed. Twenty out of 50 patients were randomly selected from our index prospective cohort (IPC): a prior study evaluating dorsal tangential views (DTVs) in reducing dorsal screw penetration in internal fixation of intra-articular distal radius fractures using post-operative CT scans to quantify screw protrusion. Pre-operative CTs from this cohort were now used for 3DVP by three experienced orthopaedic trauma surgeons (supplementary video). 3DVP was compared with the corresponding post-operative CT for assessing screw lengths and incidence of dorsal penetration. The Wilcoxon Signed Ranks test was used to compare screw lengths and the Fishers' exact for incidence of penetration.

RESULTS

Three surgeons performed 3DVP for 20 distal radius fractures and virtually applied 60 volar plates and 273 screws. Median screw length was shorter in the 3DVP when compared to IPC: 18 mm (range, 12-22) versus 20 mm (range, 14-26) (p < 0.001). The number of penetrating screws was 5% (13/273 screws) in the 3DVP group compared to 11% (10/91 screws) in the IPC (p = 0.047). Corresponding to a reduction in incidence of at least one dorsally penetrating screw in 40% of patients in the IPC group, to 18% in the 3DVP group (p = 0.069).

CONCLUSION

Three-Dimensional Virtual Pre-Operative Planning (3DVP) may reduce the incidence of dorsally penetrating screws in patients treated with volar plating for intra-articular distal radius fractures.

LEVEL OF EVIDENCE: II, diagnostic imaging study.

Для цитирования: Prijs Jasper, Schoolmeesters Bram, Eygendaal Denise, de Vries Jean-Paul P M, Jutte Paul C, Doornberg Job N, Jaarsma Ruurd L, IJpma Frank F A, Traumaplatform 3D Consortium. 3D virtual pre-operative planning may reduce the incidence of dorsal screw penetration in volar plating of intra-articular distal radius fractures.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2021. DOI: 10.1007/s00068-021-01800-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.