MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jos.2021.07.027

Медицинская библиотека · Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2021

Minimally invasive plate osteosynthesis with locking plate for metastatic humeral fractures.

Matsumura Tomohiro, Saito Tomohiro, Akiyama Toru, Takeshita Katsushi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Limited reports have examined the outcomes and complications of minimally invasive plate osteosynthesis (MIPO) with a locking plate (LP) in metastatic humeral fractures. Therefore, this study aimed to evaluate the effectiveness of MIPO in the treatment of metastatic humeral fractures.

METHODS

Patients who underwent MIPO for metastatic humeral fractures were included in this study. Data on patient demographics, new Katagiri score, operative time, amount of blood loss, bone union rate, range of motion (ROM) of the shoulder and elbow, and perioperative complications were obtained.

RESULTS

Twelve patients (seven men and five women) with 14 fractures were included in this study. The median operative time was 92.6 ± 28.9 min (range, 57-175 min) and the median amount of intraoperative blood loss was 106.1 ± 109.5 g (range, 10-330 g). No patient required surgery-related transfusion. The median duration of acquisition of active elbow ROM of>100° and active shoulder flexion of >90° were 8.9 ± 6.6 days (range, 1-30 days) and 17.5 ± 13.0 days (range, 6-47 days), respectively. The mean follow-up period was 10.0 ± 9.0 months (range, 1-33 months). There were no complications, and no patient required any further surgery for the affected humerus until death.

CONCLUSION

MIPO using an LP provided acceptable functional outcomes in advanced-stage cancer patients with metastatic humeral fractures during their limited lifetime.

Для цитирования: Matsumura Tomohiro, Saito Tomohiro, Akiyama Toru, Takeshita Katsushi. Minimally invasive plate osteosynthesis with locking plate for metastatic humeral fractures.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2021. DOI: 10.1016/j.jos.2021.07.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.