MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/ard.2010.144527

Медицинская библиотека · Annals of the rheumatic diseases · 2011

Hand osteoarthritis and MRI: development and first validation step of the proposed Oslo Hand Osteoarthritis MRI score.

Haugen Ida K, Lillegraven Siri, Slatkowsky-Christensen Barbara, Haavardsholm Espen A, Sesseng Sølve, Kvien Tore K, van der Heijde Désirée, Bøyesen Pernille

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

MRI scoring systems for hand osteoarthritis (HOA) are currently not available. The present work proposes the Oslo HOA MRI (OHOA-MRI) score and examines the intrareader and inter-reader reliability.

METHODS

Relevant HOA features were included in the initial version of the OHOA-MRI score after literature review and informal group discussions. After a training session and two calibration exercises (with three readers), features with low reliability and/or low prevalence were excluded, and feature definitions/gradings were improved. In the reliability exercise 3 readers independently evaluated MRI scans of distal interphalangeal (DIP) and proximal interphalangeal (PIP) joints in 10 patients with HOA according to the final proposed score. The reading was repeated after 1 week. Intraclass correlation coefficients (ICCs), percentage exact agreement/percentage close agreement (PEA/PCA) and smallest detectable difference were calculated.

RESULTS

The final proposed OHOA-MRI score includes assessment of synovitis, flexor tenosynovitis, erosions, osteophytes (OPs), joint space narrowing (JSN) and bone marrow lesions (BMLs) on a 0-3 scale, and absence/presence of cysts, malalignment (frontal/sagittal plane), collateral ligaments (CLs) and BMLs at CL insertion sites. Inter-reader reliability was very good for synovitis, erosions, OPs, JSN, malalignment (frontal) and BMLs (ICCs ≥ 0.83, PCA ≥ 89%), and good for flexor tenosynovitis (ICC 0.64, PCA 80%) and CL presence (ICC 0.79, PEA 63%). Cysts, malalignment (sagittal) and BMLs at CL insertion sites showed high PEA (≥ 85%), but poor to moderate ICCs (0.00-0.59). Intrareader reliability was similar. The reliability was generally highest in PIP joints.

CONCLUSIONS

The proposed OHOA-MRI score could reliably assess HOA features. However, further validation is needed.

Для цитирования: Haugen Ida K, Lillegraven Siri, Slatkowsky-Christensen Barbara, Haavardsholm Espen A, Sesseng Sølve, Kvien Tore K, van der Heijde Désirée, Bøyesen Pernille. Hand osteoarthritis and MRI: development and first validation step of the proposed Oslo Hand Osteoarthritis MRI score.. Annals of the rheumatic diseases. 2011. DOI: 10.1136/ard.2010.144527.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.