MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2011.01.031

Медицинская библиотека · European journal of radiology · 2011

Dynamic 3D-MR-angiography for assessing rheumatoid disease of the hand--a feasibility study.

Notohamiprodjo Mike, Glaser Christian, Horng Annie, Helck Andreas, Bauner Kerstin U, Reiser Maximilian F, Hatz Hans J, Weckbach Sabine

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate highly temporally resolved MR-angiography (MRA) with time-resolved imaging with stochastic trajectories (TWIST) of the hand as supplementary tool for dynamic assessment of synovitis and vascular pathologies in rheumatoid diseases.

MATERIAL AND

METHODS

A coronal dynamic TWIST-MRA-sequence (0.7 mm × 0.7 mm × 1.4 mm, temporal resolution 2.5s, time of acquisition 4 min) of the predominantly affected hand of 17 patients with suspected rheumatoid disease was acquired after contrast administration (Multihance, Bracco Imaging SpA) at 3T (Magnetom VERIO, 8-channel-knee-coil, Siemens Healthcare). As standard of reference, contrast enhanced non fat-saturated coronal and fat-saturated axial T1-w sequences were acquired. These static sequences and the dynamic TWIST-MRA-maximum-intensity-projections (MIP) were separately assessed by two readers in consensus, recording the number of synovial lesions (wrist, intercarpal, metacarpophaleangal/proximal/distal interphalangeal joints), signs of tenosynovitis and vasculitis. Diagnostic confidence was rated (4-point-scale: 4=excellent; 1=non-diagnostic). Statistical significance was tested using the Wilcoxon-rank-sum-test.

RESULTS

An insignificantly lower number of synovial lesions (n=72 vs. 89; p=0.1) and only 3/9 cases with tenosynovitis were identified by the TWIST-MRA. For detected lesions, diagnostic confidence was comparable (MRA: 3.64; static T1-w post contrast: 3.47). In patients with high clinical activity dynamic MRA showed very early synovial enhancement. Only dynamic MRA detected 3 cases of vasculitis (subsequently confirmed with digital-subtraction-angiography).

CONCLUSION

TWIST-MRA facilitates fast detection of synovitis. Although dynamic MRA of the hand is inferior to static contrast enhanced sequences in assessing the number of synovitic and tenosynovitic lesions, its high temporal resolution allows for fast visual grading of disease activity and assessment of vasculitis without additional contrast material application.

Для цитирования: Notohamiprodjo Mike, Glaser Christian, Horng Annie, Helck Andreas, Bauner Kerstin U, Reiser Maximilian F, Hatz Hans J, Weckbach Sabine. Dynamic 3D-MR-angiography for assessing rheumatoid disease of the hand--a feasibility study.. European journal of radiology. 2011. DOI: 10.1016/j.ejrad.2011.01.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.