MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00056-021-00356-5

Медицинская библиотека · Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2021

Effect of using different component combinations for orthodontic bracket bonding with self-etch primers.

Knaup Isabel, Weber Eva, Böddeker Antonia, Tempel Katrin, Rückbeil Marcia Viviane, Bartz Jenny Rosa, Bastian Asisa, Wagner Yvonne, Wolf Michael

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate bonding quality for orthodontic bracket bonding with different component combinations of self-etch primers in vitro.

METHODS

Metallic brackets were bonded to bovine lower incisors and assigned to groups. Group 1: comparison of self-etch (Transbond™ Plus, 3M™ Unitek, Neuss, Germany, n = 30; BrackFix® primer SE, VOCO®, Cuxhaven, Germany, n = 20) and etch-and-rinse bonding systems (Transbond™ XT, n = 20; BrackFix®, n = 20); group 2: comparison of different self-etch primer (Transbond™ Plus; BrackFix® primer SE) and adhesive (Transbond™ XT, n = 20; BrackFix®, n = 20) product combinations; group 3: testing cyclic fatigue bond strength of self-etch bonding systems (Transbond™ Plus, n = 20; BrackFix® primer SE, n = 20). All teeth were tested for shear bond strength according to the DIN-13990 standard, the adhesive remnant index (ARI) and enamel fractures were determined microscopically (10 × magnification).

RESULTS

The mean shear bond strength of the self-etch (Transbond™ Plus: 16.38 ± 3.68 MPa; BrackFix® primer SE: 16.24 ± 1.73 MPa) and etch-and-rinse bonding systems (Transbond™ XT: 18.45 ± 2.56 MPa; BrackFix®: 17 ± 5.2 MPa) were of a clinically adequate order of magnitude (≥ 6-10 MPa) and were not statistically different. The component combination BrackFix® primer SE/Transbond™ XT adhesive led to a significantly lower shear bond strength (11.99 ± 3.68 MPa). There were no significant differences between static and fatigue shear bond strengths of self-etch bonding systems. Mean ARI scores mostly ranged between 4 and 5. The combination of the self-etch primer Transbond™ Plus with the BrackFix® adhesive led to a significantly increased enamel fracture rate.

CONCLUSIONS

Based on the present findings bond strength of self-etch primers was equal to etch-and-rinse primers for bracket bonding. Combining different self-etch bonding systems might alter the clinical performance.

Для цитирования: Knaup Isabel, Weber Eva, Böddeker Antonia, Tempel Katrin, Rückbeil Marcia Viviane, Bartz Jenny Rosa, Bastian Asisa, Wagner Yvonne, Wolf Michael. Effect of using different component combinations for orthodontic bracket bonding with self-etch primers.. Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie. 2021. DOI: 10.1007/s00056-021-00356-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.