MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00421-014-2937-3

Медицинская библиотека · European journal of applied physiology · 2014

Faster VO(2) kinetics after eccentric contractions is explained by better matching of O(2) delivery to O(2) utilization.

Nederveen Joshua P, Major Brendan, Paterson Donald H, Murias Juan M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: This study examined the impact of eccentric exercise-induced muscle damage on the rate of adjustment in muscle deoxygenation and pulmonary O2 uptake (VO(2p)) kinetics during moderate exercise.

METHODS

Fourteen males (25 ± 3 year; mean ± SD) completed three step transitions to 90 % θL before (Pre), 24 h (Post24) and 48 h after (Post48) eccentric exercise (100 eccentric leg-press repetitions with a load corresponding to 110 % of the participant's concentric 1RM). Participants were separated into two groups: phase II VO(2p) time constant (τVO(2p)) ≤ 25 s (fast group; n = 7) or τVO(2p) > 25 s (slow group; n = 7). VO(2p) and [HHb] responses were modeled as a mono-exponential.

RESULTS

In both groups, isometric peak torque (0°/s) at Post24 was decreased compared to Pre (p < 0.05) and remained depressed at Post48 (p < 0.05). τVO(2p) was designed to be different (p < 0.05) at Pre between the Fast (τVO(2p); 19 ± 4 s) and Slow (32 ± 6 s) groups. There were no differences among time points (τVO(2p): Pre, 19 ± 4 s; Post24, 22 ± 3 s; Post48, 20 ± 4 s) in the Fast group. In Slow, there was a speeding (p < 0.05) from the Pre (32 ± 6 s) to the Post24 (25 ± 6) but not Post48 (31 ± 6), resulting in no difference (p > 0.05) between groups at Post24. This reduction of τVO(2p) was concomitant with the abolishment (p < 0.05) of an overshoot in the [HHb]/VO(2p) ratio.

CONCLUSION

We propose that the sped VO(2p) kinetics observed in the Slow group coupled with an improved [HHb]/VO(2p) ratio suggest a better matching of local muscle O2 delivery to O2 utilization following eccentric contractions.

Для цитирования: Nederveen Joshua P, Major Brendan, Paterson Donald H, Murias Juan M. Faster VO(2) kinetics after eccentric contractions is explained by better matching of O(2) delivery to O(2) utilization.. European journal of applied physiology. 2014. DOI: 10.1007/s00421-014-2937-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.