MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jor.2016.10.030

Медицинская библиотека · Journal of orthopaedics · 2016

The inflatable intramedullary nail for humeral shaft fractures.

Ozan Fırat, Gürbüz Kaan, Uzun Erdal, Gök Sefa, Doğar Fatih, Duygulu Fuat

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We assessed the results of humeral shaft fracture fixation using the inflatable intramedullary nail using radiological and clinical findings.

METHODS

From 2012 to 2015, we treated 14 patients with humeral shaft fractures using inflatable intramedullary nail after closed reduction.

RESULTS

The mean follow-up time was 14.1 months. The mean time to bone union was 4.5 months. None of the patients had major perioperative mechanical complications or postoperative complications, except for the occurrence of fixation loss and non-union in one patient.

CONCLUSION

Inflatable intramedullary nails seem to be applicable, safe and effective for humeral AO/OTA type A midshaft fractures.

Для цитирования: Ozan Fırat, Gürbüz Kaan, Uzun Erdal, Gök Sefa, Doğar Fatih, Duygulu Fuat. The inflatable intramedullary nail for humeral shaft fractures.. Journal of orthopaedics. 2016. DOI: 10.1016/j.jor.2016.10.030.