MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-021-04638-2

Медицинская библиотека · BMC musculoskeletal disorders · 2021

Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis.

Lin Shiyuan, Shang Jie, Xing Baizhou, Wu Biao, Peng Rong, Wang Gang, Lu Hua-Ding

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The optimal treatment of Pauwels type III femoral neck fracture (FNF) in young patients remains a worldwide challenge in orthopedic surgery.

METHODS

Finite element models of four internal fixations were developed to treat Pauwels type III FNF: a: the traditional inverted triangular parallel cannulated screw (PCS) model, b: the F-technique cannulated screw model, c: the modified F-technique cannulated screw model using a fully threaded screw instead of a partially threaded distally, d: the dynamic hip screw coupled with derotational screw (DHS + DS) model. Under the same conditions, finite element analyses were carried out to compare the displacement and von Mises stress distribution of four internal fixations and femurs, the maximum crack distances of the fracture surfaces, Z axis displacements of four models as well as the stress distribution in the subtrochanteric region.

RESULTS

The modified F-technique configuration resulted in a more stable fixation as compared to the other three configurations, with respect to the maximum displacement and stress peaks of femur and internal fixations, the maximum crack distances of the fracture surfaces, Z axis displacements of four configurations as well as the stress distribution in the subtrochanteric region.

CONCLUSIONS

Our results suggested that modified F-technique configuration show a better performance in resisting shearing and rotational forces in treating Pauwels type III FNF compared to those using traditional inverted triangular PCS, the F-technique configuration or DHS + DS, providing a new choice for the treatment of FNFs.

Для цитирования: Lin Shiyuan, Shang Jie, Xing Baizhou, Wu Biao, Peng Rong, Wang Gang, Lu Hua-Ding. Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis.. BMC musculoskeletal disorders. 2021. DOI: 10.1186/s12891-021-04638-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.