DOI 10.3760/cma.j.cn112137-20210204-00355

Медицинская библиотека · Zhonghua yi xue za zhi · 2021

[Biomechanical study of anterior occipital condyle screw plate system].

Peng Y J, Wang Y, Ma W H, Shi K R, Xu D L, Li H J, Zhou S Y, Zhao X C

СтатьяПеревод в очереди

Аннотация

Objective

To analyze the feasibility of anterior occipitocervical fusion biomechanical characteristic of craniovertebral reconstruction by anterior occipital condyle screw plate system.

Methods

Six cervical vertebra specimens including 4 males and 2 females were enrolled, whose mean age of death was (49.3±7.5) years. The normal models were established by soft tissue dissection, and the instability models were established by destroy bone and ligament structure including, anterior arch of the atlas, part of the lateral mass of the atlas, the odontoid process, the odontoid apical ligament, the pterygoid ligament, the transverse ligament of the atlas the joint capsule. The clivus screw fixation models were established by anterior clivus screw fixation, and then those models were performed by anterior occipital condyle screw fixation. All four groups were loaded with a 1.5 N·m continuous pure force in flexion-extension, lateral bending, and axial rotation. Then measured the range of motion of specimen C0-C1 and C0-C2. And the pull-out force test was conducted to compare the effects of unicortical and bicortical fixation on the pull-out force of screws.

Results

In the C0-C1 segment, the range of motion in flexion-extension (forward and posterior), lateral bending and axial rotation in the clivus group was 6.46°±0.85°, 5.14°±0.76°, 2.73°±0.36°, 1.12°±0.41°, respectively; and it was 5.92°±0.90°, 4.16°±1.06°, 2.86°±0.50°, 1.05°±0.27°, respectively in the occipital condyle group. As for C0-C2 segment, the range of motion in the clivus group was 9.55°±1.99°, 10.46°±2.03°, 6.90°±1.29°, 13.51°±1.37°, respectively; and it was 8.14°±1.38°, 9.53°±1.55°, 4.75°±1.06°, 7.90°±1.68°, respectively, in the occipital condyle group. The ranges of motion in the occipital condyle group were significantly lower than clivus group (all P<0.05). The maximum pull out force by bicortical fixation was significantly better than unicortical fixation ((439±33) N vs (408±28) N, P<0.05).

Conclusion

The anterior occipital condyle screw plate system provides better stability especially in anti-bending and anti-rotation than the anterior clival screw fixation.

Для цитирования: Peng Y J, Wang Y, Ma W H, Shi K R, Xu D L, Li H J, Zhou S Y, Zhao X C. [Biomechanical study of anterior occipital condyle screw plate system].. Zhonghua yi xue za zhi. 2021. DOI: 10.3760/cma.j.cn112137-20210204-00355.