OBJECTIVE

To compare the clinical efficacy of distal radius T-plate combined with suture anchor and distal clavicle anatomical locking plate combined with suture anchor in the treatment of Neer Ⅱb distal clavicle fracture.

METHODS

From June 2014 to June 2018, 42 patients with Neer Ⅱb distal clavicle fractures were retrospectively analyzed. According to different surgical methods, they were divided into the observation group (T-shaped plate combined with suture anchor) and the control group (anatomical locking plate combined with suture anchor). There were 22 patients in the observation group and 20 patients in the control group. In the observation group, there were 13 males and 9 females, aged from 22 to 70 (45.78± 14.44) years old, 12 cases on the left side and 10 cases on the right side, 8 cases of traffic accident injury and 14 cases of fall. In the control group, there were 12 males and 8 females, aged from 24 to 66 (44.17±15.58) years, 13 cases on the left side and 7 cases on the right side, 6 cases of traffic accident injuryand 14 cases of fall. The operation time, intraoperative blood loss and fracture healing time were compared between the two groups, and Constant Murley score was used to evaluate shoulder joint function.

RESULTS

The patients in both groups were followed up for 18 to 24 (20.96±2.02) months. The incisions of both groups were healed at stageⅠ. The fracture ends of both groups were bony healed at the last follow up. There was no significant difference in operation time, intraoperative blood loss and fracture healing time between two groups (P>0.05);there was no significant difference in shoulder joint function between two groups at 3 months after operation (P>0.05).

CONCLUSION

The two methods can obtain satisfactory results in the treatment of Neer Ⅱb distal clavicle fractures, especially suitable for patients with comminuted distal clavicle fractures or osteoporosis; the clinical effect of the treatment of NeerⅡb distal clavicle fractures with T type distal radius plate combined with suture anchor is satisfactory, which provides another feasible treatment scheme for clinic.

Для цитирования: Wang Jin, Wang Zhi-Xu, Li Zi-Cai, Pu Yan-Chuan, Wang Hu-Lin, Miao Sheng-Long, Bi Hu, Wang Dong, Xu Dong-Lin, Xu Zhi-Bin. [Case control study on T-plate combined with suture anchors for the treatment of Neer Ⅱb clavicle fractures].. Zhongguo gu shang = China journal of orthopaedics and traumatology. 2021. DOI: 10.12200/j.issn.1003-0034.2021.07.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.