MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/phm.0b013e3181e29c55

Медицинская библиотека · American journal of physical medicine & rehabilitation · 2010

Detection of knee effusion by ultrasonography.

Hong Bo Young, Lim Seong Hoon, Cho Ye Rim, Kim Hye Won, Ko Young Jin, Han Seung Ho, Lee Jong In

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this study was to assess which scan view was sensitive in detecting knee effusion by ultrasonography while infusing normal saline in cadaveric specimens.

DESIGN

Intraarticular injection of normal saline with contrast dye was done in increments (5, 10, 15, and 20 ml) into the knee joint of eight fresh cadavers. After infusion of each amount, sonographic images were obtained with five different scans: medial, midline, and lateral on longitudinal scans, and medial and lateral on transverse scans. When 20 ml had been injected, the knee was flexed at 30 degrees and serial images were taken.

RESULTS

After infusion of 10 ml, effusion of more than 2 mm depth with ultrasonography was most frequently seen in lateral transverse scans (14/14), and the next most frequent view was a lateral longitudinal scan (11/14). After knee flexion, the amount of effusion was increased on medial and middle longitudinal scans and was decreased on transverse scans.

CONCLUSIONS

For detecting knee effusion by ultrasonography, lateral transverse and longitudinal scans were the most sensitive in the knee extension posture. With knee flexion at 30 degrees, effusion was more readily detected on the medial and midline longitudinal scans than with knee extension.

Для цитирования: Hong Bo Young, Lim Seong Hoon, Cho Ye Rim, Kim Hye Won, Ko Young Jin, Han Seung Ho, Lee Jong In. Detection of knee effusion by ultrasonography.. American journal of physical medicine & rehabilitation. 2010. DOI: 10.1097/phm.0b013e3181e29c55.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.