DOI 10.1097/phm.0b013e3181e29c55
Detection of knee effusion by ultrasonography.
Аннотация
OBJECTIVES
The purpose of this study was to assess which scan view was sensitive in detecting knee effusion by ultrasonography while infusing normal saline in cadaveric specimens.
DESIGN
Intraarticular injection of normal saline with contrast dye was done in increments (5, 10, 15, and 20 ml) into the knee joint of eight fresh cadavers. After infusion of each amount, sonographic images were obtained with five different scans: medial, midline, and lateral on longitudinal scans, and medial and lateral on transverse scans. When 20 ml had been injected, the knee was flexed at 30 degrees and serial images were taken.
RESULTS
After infusion of 10 ml, effusion of more than 2 mm depth with ultrasonography was most frequently seen in lateral transverse scans (14/14), and the next most frequent view was a lateral longitudinal scan (11/14). After knee flexion, the amount of effusion was increased on medial and middle longitudinal scans and was decreased on transverse scans.
CONCLUSIONS
For detecting knee effusion by ultrasonography, lateral transverse and longitudinal scans were the most sensitive in the knee extension posture. With knee flexion at 30 degrees, effusion was more readily detected on the medial and midline longitudinal scans than with knee extension.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.