DOI 10.1007/s00113-021-01039-x
[Angle stable plate for treatment for insufficiency fractures of the pelvis (minimally invasive posterior locked compression plate) : Video article].
Аннотация
OBJECTIVE OF SURGERY: High primary stability of the pelvic girdle with full weight bearing.
INDICATIONS: Instability and immobility in patients with osteoporotic fractures of the pelvis.
CONTRAINDICATIONS: Decubitus ulcers, infections.
SURGICAL TECHNIQUE: Minimally invasive posterior locked compression plate 4.5 LCP (locked compression plate, DePuy Synthes, Zuchwil, Switzerland).
FOLLOW-UP: Immediate mobilization with full weight bearing, X‑ ray control.
EVIDENCE: The follow-up examination of a collective of 34 patients showed no implant loosening and a relatively low radiation exposure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.