Fracture toughness of dental incremental composite-composite interfaces at elevated temperatures.

Maier Eva, Loumprinis Nikolaos, Belli Renan, Petschelt Anselm, Eliades George, Lohbauer Ulrich

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The aim of the present laboratory study was to mechanically characterize the interface between two dental resin-based composite (RBC) increments, and to investigate if elevated temperatures have an influence on the quality of the interface mimicking clinical filling procedure. Four RBCs (CLEARFIL MAJESTY™ Posterior, Kuraray (CMP)/Filtek™ Supreme XTE, 3M (FSX)/Grandio®SO, VOCO (GSO)/VisCalor® bulk, VOCO (VCB)) were tested with a fracture toughness test using Chevron notched beams (KI,CNB) at 23, 37 and 54 °C. KI,CNB specimens (3 × 4x25mm) with a V-shaped notch at the incremental interface were loaded until failure in a 4-point bending set-up. Failure modes were characterized using light microscopy, microstructural interface was analyzed using SEM. Statistical analysis was performed using Kolmogorov-Smirnoff test, two-way ANOVA and Tukey Post-Hoc test (p = 0.05). Mean KI,CNB ranged between 0.73 ±0.14 MPam0.5 (VCB, 23 °C) and 1.11 ± 0.11 MPam0.5 (FSX, 23 °C). The tested conventional highly filled RBCs presented fracture toughness at the incremental interface comparable to the cohesive strength of the bulk materials. VCB showed reduced interfacial fracture toughness at 23 and 37 °C, but performed well at elevated temperature of 54 °C.

Для цитирования: Maier Eva, Loumprinis Nikolaos, Belli Renan, Petschelt Anselm, Eliades George, Lohbauer Ulrich. Fracture toughness of dental incremental composite-composite interfaces at elevated temperatures.. Journal of the mechanical behavior of biomedical materials. 2021. DOI: 10.1016/j.jmbbm.2021.104655.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.