MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/cre2.454

Медицинская библиотека · Clinical and experimental dental research · 2021

Effect of occlusal anatomy of CAD/CAM feldspathic posterior crowns in the stress concentration and fracture load.

Borges Alexandre Luiz Souto, Tribst João Paulo Mendes, de Lima Aline Lins, Dal Piva Amanda Maria de Oliveira, Özcan Mutlu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

This study evaluated the effect of restoration occlusal design on the maximum fracture load and stress distribution of a feldspathic ceramic crown.

MATERIALS AND

METHODS

Twenty dentin analogues were used to simulate a full-crown preparation. Next, 20 feldspathic crowns were milled according to the occlusal design parameter available in the CAD database (Young or Adult). The crowns were cemented with dual cure resin-cement and loaded until fracture at 1 mm/min crosshead speed. Data were analyzed by using one-way ANOVA and Tukey tests (p < 0.05). The same geometry and experimental setup was modeled and exported to the computer aided engineering software and tensile stress concentration was calculated using the finite element method with 300 N occlusal load simulation.

RESULTS

The occlusal anatomy significantly influenced the load-to-fracture (p < 0.05). Adult design showed higher mean values (1149 ± 201 N) than Young design (454 ± 77 N). The maximum principal stress criteria showed similar stress pattern for both designs, however, the highest stress concentration was calculated for Young design (91 MPa) in the occlusal surface.

CONCLUSIONS

An anatomy design with reduced cusp angulation and less evident occlusal sulcus can reduce the stress concentration and increase the fracture load for feldspathic CAD/CAM posterior crowns.

Для цитирования: Borges Alexandre Luiz Souto, Tribst João Paulo Mendes, de Lima Aline Lins, Dal Piva Amanda Maria de Oliveira, Özcan Mutlu. Effect of occlusal anatomy of CAD/CAM feldspathic posterior crowns in the stress concentration and fracture load.. Clinical and experimental dental research. 2021. DOI: 10.1002/cre2.454.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.