MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aott.2016.05.002

Медицинская библиотека · Acta orthopaedica et traumatologica turcica · 2016

Augmentative locking plate with autologous bone grafting for distal femoral nonunion subsequent to failed retrograde intramedullary nailing.

Ru Jiang-Ying, Cong Yu, Shi Dai, Lu Yang-Hu, Niu Yun-Fei, Xu Hai-Dong

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore the indications and efficacy of augmentative locking compression plate (LCP) or less invasive stabilization system (LISS)with autogenous bone grafting (BG) in treating distal femoral nonunion subsequent to failed retrograde intramedullary nailing (RIN).

METHODS

A retrospective study was performed for 21 patients with distal femoral nonunion subsequent to failed RIN, who received therapy with either augmentative LCP (n = 11) or LISS with autogenous BG (n = 13). Operation time, time to union, union rate, time to renonunion, complication rate and SF-36 scores a year after hardware removal were compared between the two groups.

RESULTS

The bone union occurred in 13/13 (100%) cases in augmentative LISS group versus 9/11 (81.8%) cases in augmentative LCP group [odds ratio (OR) = 3.21, 95% confidence interval (CI) 0.7-13]. Time to union, time to renonunion, complication rate of the augmentative LCP group were significantly more than that of the augmentative LISS with autogenous BG group (p = 0.023, p = 0.021 and p = 0.033). No significant difference was found in the average operation time of two groups (p = 0.121). At the follow-up a year after hardware removal, statistically significant HRQOL improvement in the augmentive LISS group was measured at the level of pain (p = 0.003) and general health perception (p = 0.011), as compared to the augmentive LCP group.

CONCLUSIONS

We suggest augmentative LCP, for distal femoral nonunios after RIN, may be optimal for that of typeAO33A fractures, whereas augmentative LISS for that of typeAO33C fractures more.

Для цитирования: Ru Jiang-Ying, Cong Yu, Shi Dai, Lu Yang-Hu, Niu Yun-Fei, Xu Hai-Dong. Augmentative locking plate with autologous bone grafting for distal femoral nonunion subsequent to failed retrograde intramedullary nailing.. Acta orthopaedica et traumatologica turcica. 2016. DOI: 10.1016/j.aott.2016.05.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.