MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-008-0679-8

Медицинская библиотека · International orthopaedics · 2008

Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement.

Holloway Ian, Walter William L, Zicat Bernie, Walter William K

СтатьяПеревод в очереди

Аннотация

This study examined the long-term results of a metal-on-metal total hip replacement with a Metasul-lined cup. Twenty-nine total hip arthroplasties were performed in 27 young patients (mean age 49 years). Twenty-two patients (23 hips) were available for clinical and radiographic analysis after a mean duration of 99 months. Mean preoperative Harris hip score of 60 improved to 93 at most recent follow-up. One patient required revision of his cup for periacetabular osteolysis. Radiographic analysis showed osteolysis in another four hips. The high rate of osteolysis found in this series has not previously been reported with this type of implant. The length of follow-up in this series is greater than other reports in the literature and may explain this difference.

Для цитирования: Holloway Ian, Walter William L, Zicat Bernie, Walter William K. Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement.. International orthopaedics. 2008. DOI: 10.1007/s00264-008-0679-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.