Modified Use of a Fibular Strut in the Reduction and Stabilization of 2-Part Osteoporotic Proximal Humerus Fractures.

Avilucea Frank R, Shaath Kareem, Kozlowski Ryan, Rezaie Nima

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study introduces a modified use of a fibular strut allograft as an adjunct to lateral locked plating in the treatment of osteoporotic two-part fractures of the proximal humerus.

METHODS

A prospective series of 13 consecutive patients (mean age 68; range, 60 to 88) with displaced two-part fractures of the proximal humerus were included. The main outcome measures included radiographic healing, clinical and radiographic findings of complications, assessment of shoulder function measured with the Shoulder Function Index, and ultrasonography assessment of rotator cuff disruption.

RESULTS

At postoperative month four, every fracture healed as evidenced on radiographic assessment. Clinically, patients achieved an average shoulder forward flexion of 141.5°, external rotation of 37°, and abduction of 98°. The mean Shoulder Function Index score was 73.2 (range, 64 to 77). No patients were included who required a major or a minor revision surgery. The average follow-up was 13.2 months (range, 12 to 15). Ultrasonography demonstrated no tears of the rotator cuff.

DISCUSSION: In a series of 13 patients, our technique facilitated fracture reduction while avoiding additional soft-tissue dissection at the fracture site and enabled supplementary stabilization after application of a lateral locking plate. Using this technique, we had minimal complications, a high rate of osseous healing, and achieved favorable clinical outcomes in a challenging patient population.

Для цитирования: Avilucea Frank R, Shaath Kareem, Kozlowski Ryan, Rezaie Nima. Modified Use of a Fibular Strut in the Reduction and Stabilization of 2-Part Osteoporotic Proximal Humerus Fractures.. Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews. 2020. DOI: 10.5435/jaaosglobal-d-20-00153.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.