OBJECTIVE

To evaluate the effectiveness of intramedullary fixation using the Kirschner-wire (K-wire) compared to the titanium elastic nail (TEN) in pediatric femoral shaft fractures.

METHODS

A sample of 42 pediatric patients with a mean age of 6.55±2.42 years (range 4-11 years) presenting femoral shaft fractures underwent intramedullary fixation using the K-wire or TEN.

RESULTS

There was no significant difference found between groups, of which 16 (38.1%) patients were treated with K-wire and 26 (61.9%) patients were treated with TEN in terms of union duration. Moreover, none of the patients showed nonunion or a delayed union.

CONCLUSIONS

The use of adjusted K-wire instead of TEN in the intramedullary fixation of femoral shaft fractures in selected children may be an advantageous surgical option due to the lower cost, easy accessibility and no need for a second surgery for implant removal. Level of Evidence III, Retrospective Study.

Для цитирования: Isik Cengiz, Kurtulmus Tuhan, Saglam Necdet, Saka Gursel, Akpinar Fuat, Sarman Hakan. KIRSCHNER WIRE VERSUS TITANIUM ELASTIC NAILS IN PEDIATRIC FEMORAL SHAFT FRACTURES.. Acta ortopedica brasileira. 2015. DOI: 10.1590/1413-785220152305145030.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.