MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2018.09.007

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2018

Adding Speckle-Tracking Echocardiography to Visual Assessment of Systolic Wall Motion Abnormalities Improves the Detection of Myocardial Infarction.

van Mourik Manouk J W, Zaar Daniëlle V J, Smulders Martijn W, Heijman Jordi, Lumens Joost, Dokter Jeffrey E, Lima Passos Valeria, Schalla Simon, Knackstedt Christian, Schummers Georg, Gjesdal Ola, Edvardsen Thor, Bekkers Sebastiaan C A M

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to investigate whether speckle-tracking echocardiography (STE) improves the detection of myocardial infarction (MI) over visual assessment of systolic wall motion abnormalities (SWMAs) using delayed enhancement cardiac magnetic resonance imaging as a reference.

METHODS

Transthoracic echocardiography was performed in 95 patients with first ST segment elevation MI 110 days (interquartile range, 97-171 days) after MI and in 48 healthy control subjects. Two experienced observers independently assessed SWMAs. Separately, longitudinal peak negative, peak systolic, end-systolic, global strain, and strain rate were measured and averaged for the American Heart Association-recommended coronary artery perfusion territories. Receiver operating characteristic analysis was used to determine a single optimal cutoff value for each strain parameter. The diagnostic accuracy of an algorithm combining visual assessment and STE was evaluated.

RESULTS

Median infarct size and transmurality were 15% (interquartile range, 7%-24%) and 64% (interquartile range, 46%-78%), respectively. Sensitivity, specificity, and accuracy of visual assessment to detect MI were 74% (95% CI, 63%-82%), 85% (95% CI, 72%-93%), and 78% (95% CI, 70%-84%), respectively. Among the strain parameters, SR had the highest diagnostic accuracy (area under the curve, 0.88; 95% CI, 0.83-0.94; cutoff value, -0.97 sec-1). The combination with STE improved sensitivity compared with visual assessment alone (94%; 95% CI, 86%-97%; P < .001), minimally affecting specificity (79%; 95% CI, 65%-89%; P = .607). Overall accuracy improved to 89% (95% CI, 82%-93%; P = .011). Multivariate analysis accounting for age and sex demonstrated that SR was independently associated with MI (odds ratio, 2.0; 95% CI, 1.6-2.7).

CONCLUSIONS

The sensitivity and diagnostic accuracy of visually detecting chronic MI by assessing SWMAs are moderate but substantially improve when adding STE.

Для цитирования: van Mourik Manouk J W, Zaar Daniëlle V J, Smulders Martijn W, Heijman Jordi, Lumens Joost, Dokter Jeffrey E, Lima Passos Valeria, Schalla Simon, Knackstedt Christian, Schummers Georg, Gjesdal Ola, Edvardsen Thor, Bekkers Sebastiaan C A M. Adding Speckle-Tracking Echocardiography to Visual Assessment of Systolic Wall Motion Abnormalities Improves the Detection of Myocardial Infarction.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2018. DOI: 10.1016/j.echo.2018.09.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.