MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/17453674.2012.727077

Медицинская библиотека · Acta orthopaedica · 2012

Is the transverse acetabular ligament a reliable cup orientation guide?

Abe Hirohito, Sakai Takashi, Hamasaki Toshimitsu, Takao Masaki, Nishii Takashi, Nakamura Nobuo, Sugano Nobuhiko

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: It is controversial whether the transverse acetabular ligament (TAL) is a reliable guide for determining the cup orientation during total hip arthroplasty (THA). We investigated the variations in TAL anatomy and the TAL-guided cup orientation.

METHODS

80 hips with osteoarthritis secondary to hip dysplasia (OA) and 80 hips with osteonecrosis of the femoral head (ON) were examined. We compared the anatomical anteversion of TAL and the TAL-guided cup orientation in relation to both disease and gender using 3D reconstruction of computed tomography (CT) images.

RESULTS

Mean TAL anteversion was 11° (SD 10, range -12 to 35). The OA group (least-square mean 16°, 95% confidence interval (CI): 14-18) had larger anteversion than the ON group (least-square mean 6.2°, CI: 3.8 - 7.5). Females (least-square mean 20°, CI: 17-23) had larger anteversion than males (least-square mean 7.0°, CI: 4.6-9.3) in the OA group, while there were no differences between the sexes in the ON group. When TAL was used for anteversion guidance with the radiographic cup inclination fixed at 40°, 39% of OA hips and 9% of ON hips had more than 10° variance from the target anteversion, which was 15°.

INTERPRETATION: In ON hips, TAL is a good guide for determining cup orientation during THA, although it is not a reliable guide in hips with OA secondary to dysplasia. This is because TAL orientation has large individual variation and is influenced by disease and gender.

Для цитирования: Abe Hirohito, Sakai Takashi, Hamasaki Toshimitsu, Takao Masaki, Nishii Takashi, Nakamura Nobuo, Sugano Nobuhiko. Is the transverse acetabular ligament a reliable cup orientation guide?. Acta orthopaedica. 2012. DOI: 10.3109/17453674.2012.727077.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.