MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-021-04265-x

Медицинская библиотека · BMC musculoskeletal disorders · 2021

A modified intrafocal pinning technique with three-dimensional planning to facilitate volar plating in dorsally comminuted AO/OTA C2 and C3 distal radius fractures.

Gui Xue-Yang, Shi Hong-Fei, Xiong Jin, Chen Yi-Xin, Wang Jun-Fei, Huang Jie, Qiu Xu-Sheng, Wang Yin-He

СтатьяПеревод в очереди

Аннотация

BACKGROUNDS: Theaim of this study was to assess the efficacy of a modified intrafocal pinningtechnique with three-dimensional (3D) planning to facilitate volar plating in dorsally comminuted intra-articular distal radius fractures.

METHODS

Intotal 35 AO/OTA type C2 and C3 fractures were finally included.The 3D digital model of the fracture was reconstructed based on preoperative computedtomographic (CT) images, with the displacement of the comminuted dorsalfragment and the intra-articular fragment analyzed for preoperative planning. During operation, amodified intrafocal pinning technique was applied percutaneously from thedorsal aspect of the radius to reduce the collapsed intra-articular fragmentfollowing volar plating. Adequate reduction was confirmed in all of patientsconsidering radial height, radial inclination and volar tilt in postoperativeradiographs.

RESULTS

No significant fracture re-displacement wasobserved in most of the cases during a mean follow-up period of 17.4 months, exceptfor two patients withthe C3 fracture. All of the patients achieved adequate clinicalROMs at 12 months postoperatively, with a mean DASH score of 12.0. Most of the patients achievedan excellent (n = 21) or good (n = 12) Gartland and Werley wrist score.

CONCLUSIONS

Ourmodified intrafocal pinning technique with 3D planning contributes to a satisfactoryclinical and radiological outcome in dorsally comminuted intra-articular distalradius fractures fixed with a volar locking plate.

TRIALREGISTRATION: Notapplicable because the design of the study is retrospective.

Для цитирования: Gui Xue-Yang, Shi Hong-Fei, Xiong Jin, Chen Yi-Xin, Wang Jun-Fei, Huang Jie, Qiu Xu-Sheng, Wang Yin-He. A modified intrafocal pinning technique with three-dimensional planning to facilitate volar plating in dorsally comminuted AO/OTA C2 and C3 distal radius fractures.. BMC musculoskeletal disorders. 2021. DOI: 10.1186/s12891-021-04265-x.