MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4317/jced.56916

Медицинская библиотека · Journal of clinical and experimental dentistry · 2021

Photoelastic analysis of conventional and locking system for treatment of mandibular angle fractures with a single plate.

de Oliveira Danilo-Louzada, de Souza-Batista Victor-Eduardo, Holobenko Letícia, Santiago-Junior Joel-Ferreira, Pellizzer Eduardo-Piza, Ribeiro-Junior Paulo-Domingos

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This photoelastic analysis evaluated stress distribution in different osteosynthesis systems, conventional and locking, used for treatment of mandibular angle fractures with a single plate.

MATERIAL AND

METHODS

Angle fractures were simulated in mandibles made of photoelastic resin. Following Champy's method, plate osteosynthesis was performed. The samples were divided into five groups: Group 1, non-fractured mandible; Group 2, two screws were installed in each segment using a conventional system; Group 3, two screws were installed in each segment using a locking system; Group 4, three screws were installed in the proximal segment and four screws in the distal segment using a conventional plate; Group 5, three screws were installed in the proximal segment and four screws in the distal segment using a locking plate. In an universal testing machine coupled to a polariscope, a load was applied to the first molar 10 times. The 50 images were randomly numbered and analyzed qualitatively and quantitatively by two raters.

RESULTS

The locking system promoted better stress distribution along the osteosynthesis. The locking system reduced stress magnitude in the distal segment, with a significant between-group difference (P≤ 0.001).

CONCLUSIONS

The locking plate/screw system can distribute stress more evenly throughout the osteosynthesis, especially when long seven-hole plates are used. Key words:Internal fracture fixation, osteosynthesis, mandibular fracture, bone plates.

Для цитирования: de Oliveira Danilo-Louzada, de Souza-Batista Victor-Eduardo, Holobenko Letícia, Santiago-Junior Joel-Ferreira, Pellizzer Eduardo-Piza, Ribeiro-Junior Paulo-Domingos. Photoelastic analysis of conventional and locking system for treatment of mandibular angle fractures with a single plate.. Journal of clinical and experimental dentistry. 2021. DOI: 10.4317/jced.56916.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.