MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2021/6649712

Медицинская библиотека · BioMed research international · 2021

Is Bridge Plating of Comminuted Humeral Shaft Fractures Advantageous When Using Compression Plates with Three versus Two Screws per Fragment? A Biomechanical Cadaveric Study.

Gomes Guilherme Seva, Zderic Ivan, Ahrend Marc-Daniel, Kojima Kodi E, Varga Peter, Belangero William Dias, Richards Geoff, Lambert Simon M, Gueorguiev Boyko

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Minimally invasive plate osteosynthesis (MIPO) is one of the generally accepted surgical techniques for the treatment of humeral shaft fractures. However, despite the high bone union rate, a variety of complications are still prevailing. Moreover, the current literature lacks data comparing the anterolateral MIPO approach using dynamic compression plates accommodating different numbers of screws. The aim of this study was to analyze the biomechanical performance of comminuted humeral shaft fractures fixed with dynamic compression plates using either two or three screws per fragment.

METHODS

Six pairs of fresh-frozen human cadaveric humeri from donors aged 66.8 ± 5.2 years were randomized to two paired study groups for simulation of bridge-plated comminuted shaft fracture type AO/OTA 12-C1/2/3 without interfragmentary bony support, using a dynamic compression plate positioned on the anterolateral surface and fixed with two (group 1) or three (group 2) screws per fragment. All specimens underwent nondestructive quasistatic biomechanical testing under lateral bending, anterior bending, axial bending, and torsion in internal rotation, followed by progressively increasing cyclic torsional loading in internal rotation until failure.

RESULTS

Initial stiffness of the plated specimens in lateral bending, anterior bending, axial bending, and torsion was not significantly different between the groups (P ≥ 0.22). However, cycles to 10°, 15°, and 20° torsional deformation and cycles to construct failure were significantly higher in group 2 compared with group 1 (P ≤ 0.03).

CONCLUSIONS

From a biomechanical perspective, no significant superiority is identified in terms of primary stability when using two or three screws per fragment for bridge compression plating of comminuted humeral shaft fractures. However, three-screw configurations provide better secondary stability and maintain it with a higher resistance towards loss of reduction under dynamic loading. Therefore, the use of a third screw may be justified when such better secondary stability is required.

Для цитирования: Gomes Guilherme Seva, Zderic Ivan, Ahrend Marc-Daniel, Kojima Kodi E, Varga Peter, Belangero William Dias, Richards Geoff, Lambert Simon M, Gueorguiev Boyko. Is Bridge Plating of Comminuted Humeral Shaft Fractures Advantageous When Using Compression Plates with Three versus Two Screws per Fragment? A Biomechanical Cadaveric Study.. BioMed research international. 2021. DOI: 10.1155/2021/6649712.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.