DOI 10.1016/j.injury.2015.08.018
Clinical comparison of two different plating methods in minimally invasive plate osteosynthesis for clavicular midshaft fractures: A randomized controlled trial.
Аннотация
AIM: The aim of this study was to compare the clinical and radiographic outcomes between two different plating methods (superior vs. anteroinferior) in minimally invasive plate osteosynthesis (MIPO) for acute displaced clavicular shaft fractures.
MATERIALS AND
METHODS
A prospective, randomized controlled trial was performed in a single centre. Nineteen patients were treated with superior plating and 18 with anteroinferior plating using the MIPO technique. A 3.5-mm locking reconstruction plate was bent preoperatively and applied to either the anteroinferior or superior aspect of the clavicle through two separate incisions. The operating time, time to union, the proportional length difference, complications, and functional outcome of the shoulder joint were evaluated using the Constant score and the University of California Los Angeles (UCLA) score.
RESULTS
There was no statistically significant difference in the Constant score and UCLA score. The mean time to union was 16.8 weeks for superior plating and 17.1 weeks for anteroinferior plating (p=0.866). The average operation time was 77.2min in superior plating and 79.4min in anteroinferior plating (p=0.491). One patient in the superior plating group showed plate failure. Despite no significant difference, one patient had nonunion in the superior plating group (p>0.999).
CONCLUSIONS
From a clinical perspective, although MIPO with anteroinferior plating provides better outcomes especially in complications without statistically significant difference, both plating methods provided satisfactory clinical and radiographic outcomes.
LEVEL OF EVIDENCE: Level I, a single-centre, prospective, randomized controlled trial.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.