MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.exer.2021.108580

Медицинская библиотека · Experimental eye research · 2021

A new collagen scaffold for the improvement of corneal biomechanical properties in a rabbit model.

Andreev Andrey Yurevich, Osidak Egor Olegovich, Grigoriev Timofei Evgenievich, Krasheninnikov Sergey Vladimirovich, Zaharov Valeriy Dmitrievich, Zaraitianc Oleg Vadimovich, Borzenok Sergey Anatolievich, Domogatsky Sergey Petrovich

СтатьяПеревод в очереди

Аннотация

Although collagen based materials are widely used in corneal tissue engineering with promising results. The usage of such materials for the improvement of corneal biomechanical properties is still unclear. In this study, we aimed to investigate a new Viscoll collagen-based membrane for the improvement of corneal biomechanical characteristics.The right eyes of 15 Chinchilla rabbits were implanted with the membrane via an intrastromal pocket, with the contralateral intact eyes as controls. At 7, 30, 90, and 180 days post-surgery, the rabbits underwent anterior segment optical coherence topography, clinical examination, and slit-lamp microscopy. Additionally, the corneal samples also underwent histological examination followed by the assessment of the biomechanical characteristics of four treated and non-treated corneas at 30, 90, and 180 days, including keratometry at 180 days, post operation. Data are presented as means ± confidence intervals with a 95% confidence level. All the operated corneas retained their transparency throughout the study. Implantation approximately doubled the central corneal thickness. Corneas became stronger by approximately 87% between 1 and 6 months after surgery (maximum fracture load, 13.3 ± 0.8 and 24.9 ± 1.4 N, respectively), and their elasticity increased by approximately 27% over the same time frame (maximum slope of the elastic region of the stress-strain curve, 11.5 ± 0.2 and 14.6 ± 1.4 N/mm respectively). We have thus proposed a new method to increase corneal thickness and strengthen the corneal tissues while preserving their transparency and demonstrated its safety and efficacy in a rabbit model over 6 months. This may be a suitable alternative to the existing corneal collagen crosslinking procedure.

Для цитирования: Andreev Andrey Yurevich, Osidak Egor Olegovich, Grigoriev Timofei Evgenievich, Krasheninnikov Sergey Vladimirovich, Zaharov Valeriy Dmitrievich, Zaraitianc Oleg Vadimovich, Borzenok Sergey Anatolievich, Domogatsky Sergey Petrovich. A new collagen scaffold for the improvement of corneal biomechanical properties in a rabbit model.. Experimental eye research. 2021. DOI: 10.1016/j.exer.2021.108580.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.