Аннотация

PURPOSE: To report the outcome after minimally invasive plate osteosynthesis (MIPO) through the deltoid-splitting approach for proximal humeral fractures.

METHODS

10 men and 30 women aged 37 to 88 years underwent MIPO through the deltoid-splitting approach using the Proximal Humerus Internal Locking System or the Locking Proximal Humerus Plate for 2-part (n=18), 3-part (n=20), and 4-part (n=2) proximal humeral fractures. The rehabilitation protocol was standardised.

RESULTS

All 40 patients were followed up at 3 months, 34 (85%) at 6 months, 30 (75%) at one year, and 13 (33%) at 2 years. Two patients had malunion. No patient had avascular necrosis, infection, nerve palsy, or nonunion. The mean Constant score at one year and 2 years was 75 and 87.5, respectively. The Constant score at 6 months correlated to that at one year (r=0.926, p<0.0001) and at 2 years (r=0.874, p=0.0001). In younger patients, improvement in the range of motion was faster. The early plateau group (those with no further improvement after 6 months) and the late plateau group (those with no further improvement after one year) did not differ significantly in age, fracture grade, or hand dominance.

CONCLUSION

MIPO for fixation of proximal humeral fractures using a locking plate is safe and effective in enabling an early return of shoulder function.

Для цитирования: Koljonen Paul Aarne, Fang Christian, Lau Tak Wing, Leung Frankie, Cheung Nigel W K. Minimally invasive plate osteosynthesis for proximal humeral fractures.. Journal of orthopaedic surgery (Hong Kong). 2015. DOI: 10.1177/230949901502300208.