MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2015.07.009

Медицинская библиотека · The Journal of hand surgery · 2015

Plate and Screw Fixation of Bicolumnar Distal Humerus Fractures: Factors Associated With Loosening or Breakage of Implants or Nonunion.

Claessen Femke M A P, Braun Yvonne, Peters Rinne M, Kolovich Gregory P, Ring David

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: To identify factors associated with reoperation for early loosening or breakage of implants or nonunion after operative treatment of AO type C distal humerus fractures.

METHODS

We retrospectively analyzed 129 adult patients who had operative treatment of an isolated AO type C distal humerus fracture at 1 of 5 hospitals to determine factors associated with reoperation for early loosening or breakage of implants or nonunion.

RESULTS

Within 6 months of original fixation, 16 of 129 fractures (12%) required reoperation for loosening or breakage of implants (n = 8) or nonunion (n = 8). In bivariate analyses, the Charlson comorbidity index, smoking, a coded diagnosis of obesity, diabetes mellitus, and radiographic osteoarthritis were significantly associated with reoperation for early loosening or breakage of implants or nonunion.

CONCLUSIONS

With the numbers available, patient factors rather than technical factors were associated with reoperation for loosening or breakage of implants and nonunion. Because of the relative infrequency of fixation problems and nonunion, a much larger study is needed to address technical deficiencies.

Для цитирования: Claessen Femke M A P, Braun Yvonne, Peters Rinne M, Kolovich Gregory P, Ring David. Plate and Screw Fixation of Bicolumnar Distal Humerus Fractures: Factors Associated With Loosening or Breakage of Implants or Nonunion.. The Journal of hand surgery. 2015. DOI: 10.1016/j.jhsa.2015.07.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.