MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2021.104485

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2021

Influence of material type, thickness and storage on fracture resistance of CAD/CAM occlusal veneers.

Albelasy Eman, Hamama Hamdi H, Tsoi James K H, Mahmoud Salah H

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The present study aimed to evaluate the effect of restoration thickness, CAD/CAM material, and 6 months of artificial saliva storage on the fracture resistance of occlusal veneers.

MATERIALS AND

METHODS

A total of 84 intact maxillary molars were sectioned 4.0 mm occlusal to the cementoenamel junction to expose the dentine. The teeth were assigned into 3 main groups according to the type of restorative material (e.max CAD, Vita Enamic, and Lava Ultimate). In each group, the teeth were allocated into 2 subgroups (n = 14) according to restoration thickness (1.0 and 1.5 mm). The veneers were adhesively bonded using dual-cure self-adhesive luting agent. A total of 42 specimens comprising half the tested subgroups were stored in distilled water for 24-h before the test. The remaining half was stored in artificial saliva at 37 ± 1 °C in an incubator for 6 months. All specimens (n = 84) were subjected to 5000 thermal cycles between 5 and 55 °C ± 2 before the fracture resistance test. The maximum force at fracture was recorded in Newton. Failure mode was analyzed using a stereomicroscope. The results were analyzed using a parametric Three-way ANOVA test.

RESULTS

The results of the Three-way ANOVA test revealed that material type and restoration thickness significantly affected fracture resistance values (p < 0.5), while 6 months of storage in artificial saliva had no significant effect on mean fracture resistance values (p˃0.5). The most common failure patterns in CAD/CAM resin composite and polymer-infiltrated ceramics were scores I and score II. For glass ceramic groups, score IV and III were more dominant.

CONCLUSIONS

All the tested CAD/CAM restorations in both thicknesses exhibited fracture resistance values exceeding normal and parafunctional bite forces. Polymer-infiltrated ceramics and CAD/CAM resin composite veneers showed more favorable fracture patterns.

Для цитирования: Albelasy Eman, Hamama Hamdi H, Tsoi James K H, Mahmoud Salah H. Influence of material type, thickness and storage on fracture resistance of CAD/CAM occlusal veneers.. Journal of the mechanical behavior of biomedical materials. 2021. DOI: 10.1016/j.jmbbm.2021.104485.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.