MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcot.2014.07.010

Медицинская библиотека · Journal of clinical orthopaedics and trauma · 2014

Management of fractures of the distal third tibia by minimally invasive plate osteosynthesis - A prospective series of 50 patients.

Paluvadi Siddhartha Venkata, Lal Hitesh, Mittal Deepak, Vidyarthi Kandarp

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Minimally invasive plate osteosynthesis (MIPO) is an established technique for fixation of fractures of the distal third tibia. Our study aimed to manage intra articular and extraarticular fractures of the distal third tibia by the minimally invasive plate osteosynthesis technique and follow them prospectively. Clinical and radiological outcomes were studied and clinical indications & efficacy of the procedure reviewed. Though many studies on the subject have been done previously, these have been retrospective reviews or small series.

METHODS

From May 2010 to May 2013, 50 patients of closed distal tibial fractures were operated by MIPO technique with a distal tibial anatomical locking plate having 4.5/5 proximal and 3.5/4 distal screw holes. The follow up duration was for 3 years.

RESULTS

The mean fracture healing time was 21.4 weeks (range 16-32 weeks) and average AOFAS score 95.06 was out of a total possible 100 points. At last follow up, superficial infection occurred in 5 patients (10%); deep infection, implant failure and malunion in 1-patient each (2%).

CONCLUSION

MIPO technique provides good, though slightly delayed bone healing and decreases incidence of nonunion and need for bone grafting. This technique should be used in distal tibia fractures where locked nailing cannot be done like fractures with small distal metaphyseal fragments, vertical splits, markedly comminuted fractures and in fractures with intra-articular extension.

Для цитирования: Paluvadi Siddhartha Venkata, Lal Hitesh, Mittal Deepak, Vidyarthi Kandarp. Management of fractures of the distal third tibia by minimally invasive plate osteosynthesis - A prospective series of 50 patients.. Journal of clinical orthopaedics and trauma. 2014. DOI: 10.1016/j.jcot.2014.07.010.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.