Analysis of mechanical variables in Hoffa fracture - A comparison of four methods by finite elements.

Freitas Anderson, Aquino Rubén Jeri, de Brito Felipe Fagundes, Bonfim Vinicius Mendes, Júnior Joubert Vieira Toledo, Daher Walter Rodrigo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Correct management of Hoffa fractures is a challenge in the clinical context. Open reduction along with internal fixation should be the therapy of choice. Mechanical trials with the main internal fixation systems conducted by individualized finite element (FEM) models, to date, have been neglected. The aim of this study was to biomechanically analyze four fixation methods for the treatment of Type II Hoffa fracture (OTA Classification: 33B3.2∗ lateral) using FEM.

METHODS

Four internal fixators were developed to treat Type II Hoffa fracture using finite elements: 4.5 mm cortical screws and 7 mm cannulated screw in anterior-to-posterior and posterior-to-anterior directions (4.5AP, 4.5 PA, 7AP and 7 PA). Under the same conditions, fractural deviation in the vertical, maximum and minimum principal and Von Mises directions in the syntheses used were evaluated.

RESULTS

The vertical displacements evaluated were 0.7 mm, 0.5 mm, 0.8 mm and 0.3 mm; the values of maximum were 6.14 Mpa, 6.15 hPa, 6.0 Mpa and 6.2 Mpa, the values obtained from minimum data were 6.26 Mpa, -6.45 Mpa, -7.3 MPa and -6.8 Mpa and the maximum values of Von Mises peak stress were 185.0 Mpa, 194.1 Mpa, 143.6 Mpa and 741.4 Mpa, for the fixation models 4.5AP, 4.5 PA, 7AP and 7 PA, respectively.

CONCLUSION

The 7 mm-cannulated screw fixation system yielded the best mechanical results evaluated by FEM in the treatment of Type II Hoffa fracture, causing a decrease in vertical displacement when used in retrograde and in Von Mises peak stress in anterograde.

Для цитирования: Freitas Anderson, Aquino Rubén Jeri, de Brito Felipe Fagundes, Bonfim Vinicius Mendes, Júnior Joubert Vieira Toledo, Daher Walter Rodrigo. Analysis of mechanical variables in Hoffa fracture - A comparison of four methods by finite elements.. Journal of clinical orthopaedics and trauma. 2020. DOI: 10.1016/j.jcot.2020.07.032.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.