MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0040-1721368

Медицинская библиотека · Revista brasileira de ortopedia · 2021

Finite Element Analysis of a Controlled Dynamization Device for External Circular Fixation.

Faria Fernando Ferraz, Gruhl Carlos Eduardo Miers, Ferro Rafaela Rebonato, Rached Rodrigo Nunes, Soni Jamil Faissal, Trevilatto Paula

СтатьяПеревод в очереди

Аннотация

Objective  To virtually prototype a device for external circular fixation of long bone fractures with controlled dynamization made of two different materials and predict their mechanical behavior by using the finite element analysis (FEA) method. Method  A software was used for 3D modeling two metal parts closely attached by a sliding dovetail joint and a high-density silicone damper. Distinctive FEAs were simulated by considering two different materials (stainless steel or titanium), modes (locked or dynamized) and loading conditions (static/point or dynamic/0.5 sec) with uniform 150 kg axial load on top of the device. Results  The finite elements (FEs) model presented 81,872 nodes and 45,922 elements. Considering stainless steel, the maximum stress peak (140.98 MPa) was reached with the device locked under static loading, while the greatest displacement (2.415 × 10 -3 mm) was observed with the device locked and under dynamic loading. Regarding titanium, the device presented the maximum stress peak (141.45 MPa) under static loading and with the device locked, while the greatest displacement (3.975 × 10 -3 mm) was found with the device locked and under dynamic loading. Conclusion  The prototyped device played the role of stress support with acceptable deformation in both locked and dynamized modes and may be fabricated with both stainless steel and titanium.

Для цитирования: Faria Fernando Ferraz, Gruhl Carlos Eduardo Miers, Ferro Rafaela Rebonato, Rached Rodrigo Nunes, Soni Jamil Faissal, Trevilatto Paula. Finite Element Analysis of a Controlled Dynamization Device for External Circular Fixation.. Revista brasileira de ortopedia. 2021. DOI: 10.1055/s-0040-1721368.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.