MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.a.31134

Медицинская библиотека · Journal of biomedical materials research. Part A · 2007

Enhanced wear resistance of modified cross-linked polyethylene by grafting with poly(2-methacryloyloxyethyl phosphorylcholine).

Kyomoto Masayuki, Moro Toru, Konno Tomohiro, Takadama Hiroaki, Yamawaki Noboru, Kawaguchi Hiroshi, Takatori Yoshio, Nakamura Kozo, Ishihara Kazuhiko

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We developed a cross-linked polyethylene (CLPE) modified with a phospholipid polymer in order to address the serious problem of osteolysis caused by wear particles derived from the polyethylene components of artificial hip joints. Our goal of preventing aseptic loosening could be achieved by avoiding any formation of CLPE wear particles or suppressing the activation of cell systems by the wear particles. We investigated the surface and wear resistance properties of 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer grafted onto the surface of CLPE (CLPE-g-MPC). The relative density of MPC polymer chains was determined by the P-O group index. Generally, polymerization times correspond to the number of polymer chains in radical polymerization. After 3.0 x 10(6) cycles in a hip joint simulator test, the steady wear rates of the untreated CLPE and CLPE-g-MPC cups with a low P-O group index were as high as 4 mg/10(6) cycles; those of the CLPE-g-MPC cups with high P-O group indexes, that is, 0.46 and 0.48, markedly decreased to -1.12 and 0.16 mg/10(6) cycles, respectively. Therefore, the grafting of an MPC polymer with high density would be essential in order to maintain the long-term wear resistance of CLPE-g-MPC as an orthopedic bearing material.

Для цитирования: Kyomoto Masayuki, Moro Toru, Konno Tomohiro, Takadama Hiroaki, Yamawaki Noboru, Kawaguchi Hiroshi, Takatori Yoshio, Nakamura Kozo, Ishihara Kazuhiko. Enhanced wear resistance of modified cross-linked polyethylene by grafting with poly(2-methacryloyloxyethyl phosphorylcholine).. Journal of biomedical materials research. Part A. 2007. DOI: 10.1002/jbm.a.31134.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.