MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jfas.2014.11.010

Медицинская библиотека · The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2015

Screw fixation diameter for fifth metatarsal jones fracture: a cadaveric study.

Scott Ryan T, Hyer Christopher F, DeMill Shyler L

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The fifth metatarsal Jones fracture is a well-documented injury occurring at the proximal diaphyseal-metaphyseal junction. Conservative versus surgical intervention has been discussed in published studies for the management of Jones fractures. Solid intramedullary fixation relies on accurate matching of the screw diameter to the intraosseous diameter. The purpose of the present cadaveric study was to determine the average intraosseous diameter of the proximal fifth metatarsal as it relates to screw size selection for Jones fracture stabilization. Twenty fresh-frozen cadaver legs were used for examination. The fifth metatarsal was completely dissected. A transverse osteotomy was performed from laterally to medially along the midline of the metatarsal. A digital caliper was used to measure the diameter of the medullary canal of the fifth metatarsal. The measurement was taken at the narrowest portion of the medullary canal just distal to the proximal metaphysis. The mean dorsal to plantar diameter of the fifth metatarsal was 6.475 ± 1.54 (range 4 to 12) mm and the mean medial to lateral diameter was 4.6 ± 0.85 (range 3 to 6) mm. Intramedullary screw fixation has shown beneficial results in the treatment protocol of fifth metatarsal Jones fractures. Our study has demonstrated that a 4.5-mm cannulated screw is the narrowest diameter screw that can be used in the average fifth metatarsal and still obtain adequate intraosseous purchase. When selecting the appropriate screw, the surgeon must be comfortable selecting the largest screw that will achieve the maximal interface with the dense cortical bone in both the medial to lateral and dorsal to plantar plane.

Для цитирования: Scott Ryan T, Hyer Christopher F, DeMill Shyler L. Screw fixation diameter for fifth metatarsal jones fracture: a cadaveric study.. The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons. 2015. DOI: 10.1053/j.jfas.2014.11.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.