MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jopr.13325

Медицинская библиотека · Journal of prosthodontics : official journal of the American College of Prosthodontists · 2021

Fracture Strength of Interim CAD/CAM and Conventional Partial Fixed Dental Prostheses.

Sadid-Zadeh Ramtin, Zirkel Cory, Makwoka Seteven, Li Rui

СтатьяПеревод в очереди

Аннотация

PURPOSE: To compare the fracture strength of three-unit provisional partial fixed dental prostheses (FDPs) fabricated by an indirect-direct technique from poly(methylmethacrylate) (PMMA) through digital and conventional workflows, and FDPs fabricated by a direct technique using Bisacryl (BisA) and externally reinforced BisA.

MATERIALS AND

METHODS

Forty partially edentulous typodonts with a missing mandibular left first molar and standard preparations on mandibular left second premolar and molar were used to fabricate three-unit provisional FDPs. Two materials and two techniques were used to fabricate a total of forty provisional FDPs: (1) BisA; (2) BisA reinforced with glass fiber strips [BisA-GFR]; (3) conventionally fabricated PMMA shell relined with PMMA [C-PMMA]; (4) CAD/CAM fabricated PMMA shell relined with PMMA [CAD/CAM-PMMA]. Provisional FDPs were then luted onto the preparations using a temporary cement. Specimens were mounted onto a chewing simulator; 20,000 cycles of 70 N forces were applied under 25°C distilled water. Specimens were then loaded to fracture using a universal testing machine (The Dillion Quantrol TC2i; Mecmesin) with a crosshead speed of 2 mm/min. One-way ANOVA, followed by Tukey post hoc test, was used to assess the effect of production technique on the fracture strength of the provisional FPDs (α = 0.5).

RESULTS

Mean fracture strengths recorded for the CAD/CAM-PMMA, C-PMMA, BisA, and BisA-GFR groups were 520 N, 448 N, 245 N, and 169 N, respectively. PMMA groups had significantly (p < 0.0001; F = 24.40) higher fracture strength compared to Bisacryl groups.

CONCLUSION

When high occlusal forces are expected, provisional FDPs fabricated with PMMA using the indirect-direct technique are recommended, irrespective of CAD/CAM or conventional workflow.

Для цитирования: Sadid-Zadeh Ramtin, Zirkel Cory, Makwoka Seteven, Li Rui. Fracture Strength of Interim CAD/CAM and Conventional Partial Fixed Dental Prostheses.. Journal of prosthodontics : official journal of the American College of Prosthodontists. 2021. DOI: 10.1111/jopr.13325.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.