Nich C, Bizot P, Nizard R, Sedel L

Сравнительное исследованиеАннотация на английскомСтатьяПеревод в очереди

Аннотация

PURPOSE OF THE STUDY: Management of bone stock loss remains one of the most challenging problems for revision hip surgery. The aim of this retrospective study was to report the preliminary results of peri-prosthetic femoral defect reconstruction with impacted granules of calcium phosphate ceramic.

MATERIAL AND

METHODS

Fourteen hips in 13 patients (3 men and 10 women) were evaluated. Age at surgery ranged from 30 to 79 years (mean 66.1 years). All revised devices had been cemented. Femoral revision was indicated for loosening in eleven hips (including six septic cases), femoral osteolysis (one hip), persistent pain (one hip), and recurrent dislocation (one hip). On the preoperative radiological evaluation, bone defects were assessed as SOFCOT grade II in seven case, and grade III in fourteen. None was rated grade IV. Once the loose prosthesis had been removed, bone graft or ceramic granules (14 cases) were firmly impacted in the femoral canal. The stem was standard and always cemented using modern cementing technique.

RESULTS

At a mean follow-up of 34 +/- 15 months (range 14-76 months), eleven of fourteen hips were rated good or very good according to the Postel-Merle-d'Aubigné score. One diaphyseal femoral fracture occurred and later united. Two hips required re-revision (one aseptic femoral loosening, one septic recurrence). Direct bonding between synthetic graft and bone was observed on standard radiographs in eleven cases. Stem subsidence occurred in two cases and was limited (mean 4.5 mm).

DISCUSSION: Femoral bone reconstruction using impacted calcium phosphate ceramic in revision hip arthroplasty provided encouraging results in the short to mid term. Femoral stock restoration was achieved in the great majority. No adverse effect related to the use of a synthetic graft was noted. Further long-term evaluation is required before wider application.

Для цитирования: Nich C, Bizot P, Nizard R, Sedel L. [Femoral reconstruction with impacted macroporous calcium phosphate ceramic in revision hip arthroplasty].. Revue de chirurgie orthopedique et reparatrice de l'appareil moteur. 2006. DOI: 10.1016/s0035-1040(06)75764-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.