MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/10255842.2020.1867114

Медицинская библиотека · Computer methods in biomechanics and biomedical engineering · 2021

A comparative finite element simulation of locking compression plate materials for tibial fracture treatment.

Beirami Sami, Nikkhoo Mohammad, Hassani Kamran, Karimi Alireza

СтатьяПеревод в очереди

Аннотация

The locking compression plate (LCP) system has several advantages in fracture fixation combining angular stability with the use of locking screws with traditional fixation techniques. However, the system is complex and requiring careful attention to biomechanical principles and good surgical technique. Due to the set of complicate stresses and strains in the LCP system after implantation, the material, which is being used here, is deemed important. However, so far the materials have been limited to the stainless steel (SS) or titanium (Ti). This study was therefore aimed at investigate the biomechanical performance of the internal tibial locked plates at different material properties, including SS, Ti, carbon/polyether ether ketone (PEEK) composite, in treating medial tibial fracture using patient-specific finite element (FE) model of the human tibia. The carbon/PEEK composite materials were used at three different fiber plies configurations. Simulated loading was applied at 60:40 ratios on the medial:lateral aspect. The model was fixed distally in all degrees of freedom. The results revealed the highest stress (307.10 MPa) and the lowest strain (0.14%) at Ti LCP system. The carbon/PEEK LCP system at configuration I and III showed low stress (∼60 MPa) and high strain (0.70%), which are suitable points for designing of an internal LCP system. On the other hand, the highest value of stress in callus region was 4.78 MPa (Carbon PEEK/Configuration I) and the strain variations of callus region were between 1.46% and 3.82% among all materials. These results implied the advantage of carbon/PEEK composite materials in LCP system as they can tolerate higher strains at lower stresses.

Для цитирования: Beirami Sami, Nikkhoo Mohammad, Hassani Kamran, Karimi Alireza. A comparative finite element simulation of locking compression plate materials for tibial fracture treatment.. Computer methods in biomechanics and biomedical engineering. 2021. DOI: 10.1080/10255842.2020.1867114.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.