MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2020.110192

Медицинская библиотека · Journal of biomechanics · 2020

Biphasic plating improves the mechanical performance of locked plating for distal femur fractures.

Epari Devakara R, Gurung Roshan, Hofmann-Fliri Ladina, Schwyn Ronald, Schuetz Michael, Windolf Markus

СтатьяПеревод в очереди

Аннотация

Internal fixation by plate osteosynthesis is the gold standard treatment for distal femur fractures. Despite improvements that preserve the biological conditions for bone healing, there are concerns standard locked plating constructs may be overly stiff. Biphasic plating is a novel concept designed to provide suitable fracture motion and increased implant strength to support early full weight-bearing. This study aims to demonstrate that the Biphasic Plate can be incorporated into a pre-contoured distal femur plate while providing adequate flexibility and increased implant strength. The mechanical performance of the Biphasic Plate (BP) was investigated in comparison to a standard locking plate for the distal femur (LCP-DF). Constructs were formed by mounting the implants on a bone substitute. The construct stiffness and strength under axial loading and the magnitude of interfragmentary movement were determined using finite element analysis. The Biphasic Plate exhibited a bi-linear stiffness response; at low loads, the BP construct was 55% more compliant and at high loads 476% stiffer than the LCP-DF. The Biphasic Plate provided more consistent interfragmentary movement over a wider loading range. At partial weight-bearing loads, the Biphasic Plate produced larger interfragmentary movements (0.18 vs. 0.04 mm). However, at loads equivalent to full weight-bearing, the maximum movements were substantially smaller than the LCP-DF construct (1.5 vs. 3.5 mm). The increased flexibility at low loads was provided without sacrificing implant strength with peak stress in the Biphasic Plate 63% lower than the LCP-DF construct. The biphasic plating concept can be successfully incorporated into anatomically contoured distal femur plates while providing adequate flexibility and increasing implant strength.

Для цитирования: Epari Devakara R, Gurung Roshan, Hofmann-Fliri Ladina, Schwyn Ronald, Schuetz Michael, Windolf Markus. Biphasic plating improves the mechanical performance of locked plating for distal femur fractures.. Journal of biomechanics. 2020. DOI: 10.1016/j.jbiomech.2020.110192.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.