MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2005.12.039

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2006

A new technique for femoral and tibial tunnel bone grafting using the OATS harvesters in revision anterior cruciate ligament reconstruction.

Said Hatem G, Baloch Khalid, Green Marcus

СтатьяПеревод в очереди

Аннотация

Revision anterior cruciate ligament (ACL) reconstruction is becoming more frequent, especially in specialized centers, because of the large numbers of primary ACL procedures performed. In 2-stage revisions, bone grafting of the tunnels may be undertaken if the primary position was inaccurate or if osteolysis has caused widening of the tunnels. This will allow the desired placement of the new tunnels without the risk of loss of structural integrity. It is technically difficult to deliver and impact bone graft into the femoral tunnel with the standard surgical and arthroscopic instruments. We describe a new technique for femoral and tibial tunnel impaction grafting in 2-stage ACL revisions, using the OATS grafting instruments (Osteochondral Autologous Transfer System; Arthrex, Naples, FL). The appropriately sized OATS harvester is chosen 1 mm larger than the tunnel size and is used to harvest bone graft from the iliac crest through a percutaneous approach. This provides a cylindrical graft, which is delivered to the femoral tunnel through the arthroscopic portal. The inside punch of the harvester is tapped and this allows delivery of the graft in a controlled manner and its impaction into the tunnel. The same is repeated for the tibial tunnel while providing support for the proximal end of the tunnel.

Для цитирования: Said Hatem G, Baloch Khalid, Green Marcus. A new technique for femoral and tibial tunnel bone grafting using the OATS harvesters in revision anterior cruciate ligament reconstruction.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2006. DOI: 10.1016/j.arthro.2005.12.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.