MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.dental.2020.10.018

Медицинская библиотека · Dental materials : official publication of the Academy of Dental Materials · 2020

Scattering and phase-contrast X-ray methods reveal damage to glass fibers in endodontic posts following dental bur trimming.

Soares Ana Prates, Baum Daniel, Hesse Bernhard, Kupsch Andreas, Müller Bernd R, Zaslansky Paul

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

There is concern that the integrity of fiberglass dental posts may be affected by chairside trimming during treatment. We hypothesize that hard X-ray methods of phase contrast-enhanced micro-CT (PCE-CT) and synchrotron based X-ray refraction (SXRR) can reliably identify and help characterize the extent of damage.

METHODS

Fiberglass posts were imaged both as manufactured and following trimming with a diamond bur. Each of the posts was imaged by SXRR and by PCE-CT. Datasets from PCE-CT were used to visualize and quantify 2D and 3D morphological characteristics of intact and of damage-affected regions caused by trimming.

RESULTS

The SXRR images revealed fiber inhomogeneities from manufacturing with a significant increase in internal surfaces in sample regions corresponding to damage from trimming. PCE-CT volumes unveiled the micromorphology of single fibers in the posts and some damage in the trimmed area (e.g. fractures, splinters and cracks). Area, perimeter, circularity, roundness, volume and thickness of the glass fibers in the trimmed area were statistically different from the control (p < 0.01).

SIGNIFICANCE: The integrity of single fibers in the post is critical for bending resistance and for long-term adhesion to the cement in the root canals. Damage to the fibers causes substantial structural weakening across the post diameter. Glass fragments produced due to contact with the dental bur may separate from the post and may significantly reduce bond capacity. The above mentioned synchrotron-based imaging techniques can further facilitate assessment of the structural integrity and the appearance of defects in posts (e.g. after mechanical load).

Для цитирования: Soares Ana Prates, Baum Daniel, Hesse Bernhard, Kupsch Andreas, Müller Bernd R, Zaslansky Paul. Scattering and phase-contrast X-ray methods reveal damage to glass fibers in endodontic posts following dental bur trimming.. Dental materials : official publication of the Academy of Dental Materials. 2020. DOI: 10.1016/j.dental.2020.10.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.