BACKGROUND

We studied the ability of DEXA to detect bony defects around cementless acetabular components in total hip arthroplasty. The aim of our study was to provide a tool for detection and quantification of osteolytic lesions for the planning of revision cases.

METHODS

We measured BMC in 10 human pelvis specimens retrieved from post mortem. We created standardized defects behind inserted acetabular components and compared the ash weights of the removed bone to the corresponding BMC measurements.

RESULTS

We found a good correlation between the BMC differences measured and the corresponding ash weights.

INTERPRETATION: We conclude that DEXA can detect even small defects in the bone adjacent to the cup.

Для цитирования: Laursen Mogens B, Nielsen Poul T, Søballe Kjeld. Detection of bony defects around cementless acetabular components in total hip arthroplasty: a DEXA study on 10 human cadavers.. Acta orthopaedica. 2006. DOI: 10.1080/17453670610045939.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.